Type: Lithium Metal Battery
Cathode Material: Limno2
Rechargeable: No
Size: Small
Capacity: 170mAh
Transport Package: Carton
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2011

Suppliers with verified business licenses

Hubei, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
In-stock Capacity
The supplier has In-stock capacity
to see all verified strength labels (17)

Basic Info.

Model NO.
CR1/3N
Specification
CE, SGS, ISO9001
Trademark
Forte
Origin
Hubei
HS Code
8650000
Production Capacity
10000000

Product Description

   
 

Wuhan Forte Energy Co., Ltd.

PRODUCT SPECIFICATION

 
Product Lithium manganese dioxide battery
Model Number CR1/3N/CR11108
  Outer Dimension  Φ11.6*10.8                                           
Drafted Bi Shuang Checked Liu Yao
Approved
 
Xu Chuan
 2021-01 -21     2021- 01 -21     2021-01 -21
              
 
1  Application Scope
The specification describes standard parameters, electrical characteristics, safety performance, environmental adaptability, test and judgment, operation instructions and safety regulations of the battery.
 
2  Standard Parameters
No. Item Parameter Notes
1 Capacity 170mAh  
2 Discharge current 3mA  
3 Cut-off voltage 1.5V  
4 Open-circuit voltage 3.00~3.40  
5 Max. continuous discharge current 80mA  
6 Max. pulse current 160mA  
7 -20ºCdischarge  (3mA/1.5V) >120mAh  
8 Operating Temperature -40ºC~70ºC  
9 Storage Temperature 0ºC~40ºC  
10 Weight 3g  
11 Dimension(dia *height) 11.5±0.1)*(10.6±0.2)mm  
12 Shelf life 10years  
   
 
  3 Performance Standard
3.1 Appearance
The surfaces of the batteries are clean. There should not be deformation,rust,stain or leakage.

3.2 Standard testing conditions
Unless otherwise specified elsewhere, tests should be conducted at
Temperature:25±5ºC Humidity:45~75% barometric pressure:86~106kpa

3.3 Leakage Resistance
After 24 hours at 70 ºC, the battery was placed at room temperature for 8 hours for visual inspection. There was no leakage, explosion and fire.
 
3.4 Discharge Curve



3.5 Safety Performance
Item  Test method Standard
 External short-circuit
(55ºC)
 
After the shell temperature of the tested battery is stable at 55 ºC, conduct external short circuit to the battery at this temperature, and the total resistance of the external circuit shall be less than 0.1 Ω. The short circuit shall be continued for at least 1 h after the temperature of the battery shell falls back to 55 ºC. Continue to observe the samples for 6 hours. No explosion
 
No fire
 
 Free Fall  the battery without being discharged falls on the concrete surface from a height of 1 m, each battery shall be dropped 6 times, twice in X, y and Z axes, and then the tested battery shall be placed for 1 h.  No leakage,
No explosion
No fire
high temperature
 
Put the test battery in the oven, raise the temperature to 130 ºC at the speed of 5 ºC / min, and keep at this temperature for 10 min No leakage,
No explosion
No fire
"3+1"reverse charge
(single battery)
The tested battery is connected in series with three non discharged batteries of the same model containing a single battery, and the tested battery is connected in reverse with other batteries. The resistance of the circuit shall not be more than 0.1 Ω. Turn on the circuit for 24 hours ,or until the temperature of the battery shell returns to the ambient temperature.    
No explosion
No fire
Heat shock The tested battery was placed at 75 ºC for at least 6 hours, and then at - 40 ºC for at least 6 hours. The conversion time of different temperatures should not exceed 30 min. After 10 cycles, each battery was placed at ambient temperature for at least 24 h.     
No leakage,
No explosion
No fire

3.6 Mechanical safety performance
Item Test method Standard
Vibration test The tested battery shall be firmly fixed on the vibration platform of the vibration equipment in such a way that the vibration can be truly transmitted without deformation of the battery. The vibration amplitude of sine wave was 0.8mm. In three mutually perpendicular fixed directions, 12 cycles were carried out in each direction, and the cycle time of each azimuth was 3h. One of the orientations should be perpendicular to the end face of the battery.   
No leakage,
No explosion
No fire
Crush Test The long axis of the tested battery is squeezed between the two planes by applying pressure through a vise or a hydraulic cylinder with a cylindrical piston. From the initial contact point, the extrusion is carried out continuously at a speed of about 1.5 cm / s until the extrusion force reaches about 13 kn and the pressure is released immediately. The pressure can be applied through a hydraulic cylinder with a piston diameter of 32 mm until the pressure reaches 17 MPa (13 KN). Each single cell or cell battery is extruded only once. Observe the battery for at least 6 h. No leakage,
No explosion
No fire
Shock test The tested battery is fixed on the testing equipment with a rigid support which can support all fixed surfaces of the tested battery. Each battery is subjected to three times of impact in three mutually perpendicular fixed directions, a total of 18 times.
Impact parameters
Battery type waveform
 
 peak acceleration pulse duration Number of impacts per axle shaft
Small half-sine wave 150g 6ms 3
No explosion
No fire

4. 

Precautions for Used
 
  The battery has an explosion resistant construction. But the following cautions should be taken, because combustible materials such as lithium metal and organic electrolyte are contained in the battery.  
* Do not use except inapplicable model or equipment  
* Do not connect more than three cells in series  
* Do not mix different types (chemistries) of batteries  
* Do not short circuit.  
* Do not dispose in fire  
* Do not charge.  
* Do not disassemble  
* Do not connect the wrong polarity (+,-)  
 
5.  Important Notes (Warranty)
  5.1 Warning Fire and burn hazard. Do not recharge,short circuit,over discharge, crush,disassemble, heat above 100ºC(212°F)or incinerate. Keep battery far away from children put them in original package until ready to use. Dispose of used batteries promptly.
 
     
 
  5.2 When customer does any work on the battery ignoring instructions in this specification, for example wire is soldered to the tab or battery surface directly; Jiangmen Hongli Energy, Co Ltd. cannot warrant any battery performance including safety and the customer should undertake the responsibility of all damage caused by this battery.
   
 
  5.3 Do not solder the battery directly. Excessive heating may cause deformation of the battery components such as the gasket, which may lead to the battery swelling, leakage, explosion or ignition.High temperature and long time may cause heat gathered..
 
  5.4 Observe the soldering condition for the tabbed battery to be specified by the manufacturer. Choose the tabbed battery if soldering is required.
Excessive heating may cause deformation of the gasket, leakage or performance deterioration of the battery.
 
  5.5 Tabs can be soldered on the battery terminals directly by spot-welding. The parameters of the spot-welder must be adjusted carefully to avoid the battery being perforated, changing voltage and temperature rising above 65ºC Assure not to exceed the battery temperature higher than 60ºC at soldering.

  5.6 Battery characteristics vary with type and grade, even when batteries are the same size and shape. When replacing batteries with new ones, be sure to carefully check the symbols and numbers on each battery.
 
  5.7 Please design equipment so that infants cannot easily remove batteries and swallow them.


3.0V Disposable Primary Non Rechargeable Lithium Battery Cr1/3n for Medical Instruments3.0V Disposable Primary Non Rechargeable Lithium Battery Cr1/3n for Medical Instruments3.0V Disposable Primary Non Rechargeable Lithium Battery Cr1/3n for Medical Instruments3.0V Disposable Primary Non Rechargeable Lithium Battery Cr1/3n for Medical Instruments3.0V Disposable Primary Non Rechargeable Lithium Battery Cr1/3n for Medical Instruments3.0V Disposable Primary Non Rechargeable Lithium Battery Cr1/3n for Medical Instruments3.0V Disposable Primary Non Rechargeable Lithium Battery Cr1/3n for Medical Instruments







   
















   






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
137
Year of Establishment
2020-05-11